Fusion R800RAID
Please click the arrow next to the category to expand or collapse:
Driver (4)
Firmware (0)
No Firmware was found for product.
 
Manual (5)
FAQ (11)
IDArticle TitlePost Date
91 Installation of the Sonnet (ATTO OEM) RAID card in an 8-core Mac Pro with a Fusion D800RAID, R800RAID, or D400RAID storage system.May-12-09
98 ATTO R380 RAID Software (Feb. 2008)Aug-05-09
101 Fusion storage system activity lights are always on with Seagate ES.2 (Enterprise) drives installed in the drive bays.Oct-22-10
202 Under Mac OS X 10.5.6, the PCI Express Expansion Slot Utility (early Mac Pro) always reports 8x, 1x, 1x, 16x no matter how its set.May-06-09
The bus lanes actually get set correctly under Mac OS X 10.5.6 but they are not reported correctly in the Expansion Slot Utility. The actual settings can be verified by booting under another version of Mac OS X. Sonnet has filed a bug report with Apple.
 
301 Formatting a drive array greater than 16TB with APT (Apple Partition Table) fails in a Macintosh.Jun-16-09
387 How do I replace a failed drive under warranty if I'm in a sensitive/classified environment and can't send the old one back?Mar-23-10
445 What is the default drive timeout in Fusion RAID systems? Should I change it?Mar-24-10
The default drive timeout Fusion RAID systems is 30 seconds. The default is generally the best, but may be insufficient for some Seagate drives, which in rare instances may not respond within a 30 second timeout and consequently appear as degraded. If you are using Seagate drives, Sonnet recommends setting the timeout to 60 seconds, with the CLI command, "set raidcommandtimeout 60000".
 
450 My storage shows 10% more capacity under OS X 10.6 than under OS X 10.5. Why?Mar-24-10
775 Does the ATTO R380 Support OS X 10.9 (Mavericks)?Oct-21-13
788 Can I use an ATTO R680 with the R800RAID or D800RAID?Jun-24-14
955 Can I use Seagate Iron Wolf drives; or Hitchai and WD drives 8TB and larger?May-31-18
Some newer drives use a hole pattern different from the traditional drive hole pattern for the bottom mounting points. The location of the bottom holes close to the connector did not change; however, the bottom holes near the middle have been removed and replaced with bottom holes close to the front of the drive.

The drives with the new bottom hole pattern include:
Seagate Iron Wolf drives (also missing the middle hole from the side mount hole troika)
Hitachi drives 8TB and larger
WD drives 8TB and larger

Incompatible mount holes
Echo 15+ Dock (side mount, but needs middle hole, so incompatible with only Seagate Iron Wolf)
Fusion F3 (bottom mount)
Fusion D400Q/R400P/D500P (bottom mount)
Fusion D800/R800 (bottom mount)

Compatible mount holes
Fusion R400S RAID (side mount)
Fusion R400 RAID USB 3 (side mount)
Fusion DX800/RX1600 (side mount) If using Iron Wolf line, must use Iron Wolf Pro with rotational vibration sensors